Formulas Used in Hydropower Turbine Selection Calculator
The calculator uses the following formulas to select and evaluate turbines:
Net Head:
\\[ h_{\text{net}} = h_{\text{gross}} – h_{\text{loss}} \\]Power Output:
\\[ P = \eta \cdot \rho \cdot g \cdot Q \cdot h_{\text{net}} / 1000 \\]Specific Speed:
\\[ N_s = \frac{N \sqrt{P}}{h_{\text{net}}^{5/4}} \\]Suitability Score: Based on head and specific speed ranges for each turbine type.
Where:
- \\( h_{\text{net}} \\): Net head (m)
- \\( h_{\text{gross}} \\): Gross head (m)
- \\( h_{\text{loss}} \\): Head loss (m)
- \\( P \\): Power output (kW)
- \\( \eta \\): Turbine efficiency (0 to 1)
- \\( \rho \\): Water density (1000 kg/m³)
- \\( g \\): Gravitational acceleration (9.81 m/s²)
- \\( Q \\): Flow rate (m³/s)
- \\( N_s \\): Specific speed (metric, rpm)
- \\( N \\): Rotational speed (rpm)
Example Calculations
Example 1: High-Head Site
Input: Gross Head = 200 m, Head Loss = 10 m, Flow Rate = 0.5 m³/s, Rotational Speed = 1500 rpm, Desired Power = 800 kW
Pelton (head 50–1000 m, \\( N_s \\) 10–50): Score = 92 (in range).
Result: Recommended Turbine = Pelton, Efficiency = 0.85–0.90, Power = 820.91 kW.
Example 2: Medium-Head Site
Input: Gross Head = 50 m, Head Loss = 3 m, Flow Rate = 2.0 m³/s, Rotational Speed = 1500 rpm, Desired Power = 800 kW
Francis (head 10–400 m, \\( N_s \\) 50–250): Score = 95 (in range).
Result: Recommended Turbine = Francis, Efficiency = 0.88–0.93, Power = 829.43 kW.
Example 3: Low-Head Site
Input: Gross Head = 10 m, Head Loss = 0.5 m, Flow Rate = 5.0 m³/s, Rotational Speed = 1500 rpm, Desired Power = 400 kW
Kaplan (head 2–70 m, \\( N_s \\) 250–1000): Score = 90 (in range).
Result: Recommended Turbine = Kaplan, Efficiency = 0.90–0.95, Power = 429.03 kW.